Press the left button, drag the mouse, rotate the cube, see more information

Limit Discounts

Through this webpage, choose online customer service communication, or message board. Leave your needs and get limited time discounts, up to 10% off, saving you a fortune. This discount has an indefinite period, and places are limited on a first-come, first-served basis.

Payment Method

We support various payment methods:
T/T payment
VISA
paypal
MasterCard
Alipay etc
Save time in your buying process.

Certified Product

The company's products have passed multiple national
certifications:
for example:
United States: ASME
EU: CE
Eastern Europe: EAC
Russia: GOST
Singapore: MOMO
etc
Buy products, buy with confidence, use with confidence

Product Type

Domestic hot water and heating series: gas hot water boiler, vacuum hot water boiler, vertical atmospheric pressure hot water boiler, electric hot water boiler Factory use, high temperature steam: wns fuel gas steam boiler, szs water tube steam boiler, vertical steam boiler, electric steam boiler

About Us

FANGKUAI is founded in 1998, which is a clean fuel boiler enterprise integrating R&D, manufacturing, sales and service. In the past 20 years of development and innovation, the company has grown into a global enterprise, and its products have been exported to more than 80 countries including Russia, Mongolia and Thailand, and have established long-lasting cooperative relations with local enterprises!

Contact Us

If you are interested in our company or products, you can contact with us through online consulting, demand table submission, e-mails and telephones. Our staff shall wholeheartedly provide product information, application knowledge and good service for you.

Chlorides in the boiler water - MarineProHelp

  • Offshore price : $20000-$100000 Get a quote on the right form
  • Minimum order quantity : 1 set :Chlorides in the boiler water - MarineProHelp
  • Supply Capacity : 10 units/month :Chlorides in the boiler water - MarineProHelp
  • Manufacturer/Brand : Fangkuai boiler
  • Port : Anyang
  • payment terms : Letter of Credit, Wire Transfer, VISA

Leave Your Message And Get Price!

I need the quotation of , the fuel is , this capacity is , use for . My Name is , my Email is , my WhatsApp is , Please Send the detail information for me!

Popular products

HOT

θrion Gas Fired Steam Boiler

Capacity:1-20t/h

Rated thermal efficiency: 100-104%

Fixed working pressure: ≤1.6MPa

Applicable fuel:natural gas etc.

consult
HOT

Gas(oil) Fired Integrated Hot Water Boiler

Capacity:0.7-14MW

Rated thermal efficiency:96-98%

Fixed working pressure:≤1.25MPa

Applicable fuel:Natural gas, light oil, etc.

consult
HOT

H6 Gas Fired Hot Water Boiler

Capacity:0.7-2.8Mw

Rated thermal efficiency: 97.2-106%

Fixed working pressure:0.1MPa

Applicable fuel:Natural gas, etc.

consult
HOT

T7 Vacuum Hot Water Boilerr

Capacity:2.8-7.0Mw

Rated thermal efficiency:≥105.5%

Fixed working pressure:-0.02MPa

Applicable fuel:Natural gas, etc.

consult
HOT

V6 Gas Fired Hot Water Boiler

Capacity:99Kw

Rated thermal efficiency:97.2-104.4%

Fixed working pressure:1.0MPa

Applicable fuel:Natural gas, etc.

consult
HOT

Electric Steam Boiler

Capacity:0.5-4.0 t/h

Rated thermal efficiency:98%

Fixed working pressure:≤1.25MPa

Applicable fuel:electric energy

consult

Leave us a message

We will send out plans and quotations within five minutes

Name (optional)

Email

Whatsapp

Choose product type

Message

boilermanufactory

Get display discount

boiler
Contact us

Global Sales Hotline:
0086-371-60922096

Email: [email protected]

Voicemail
  • chlorides limits in high pressure fire tube water boiler

    WATER TREATMENT . BOILERS. water in the Water Tube Boiler and heat in the Fire Tube Boiler is Chloride reading of the boiler water is 6 times the . Rules for construction of heating boilers, Boiler and Pressure high pressure steam or water, switch contacts for low water cutoff, high limits, Characteristics of boiler feed water.Get Price

  • Draft Losses In Boilers - production.cumuluspro.com

    draft losses in boilers chapter 24 fuel gas residential code 2015 of utah upcodes. training on boilers magadi thermodyne. air amp draft system eecpowerindia com. draft control system design simulation and test for a high. getting the most from boilers stormeng com.Get Price

  • Chloride limits in boiler water - Steam Forum and Power Forum

    Chloride level in Boiler feed water - Corrosion The amount of chloride in the boiler water is a function of the type of boiler and the boiler pressure. High pressure utility boilers have essentially zero chlorides. For low pressure industrial boilers say 150 psi units, boiler water chlorides limits are set on the ideas that:Chlorides & Steam Get Price

  • PREVENTION OF CHLORIDE CORROSION IN BIOMASS …

    boilers [7]. However, this approach may cause a number of operational problems related to increased slagging and corrosion of the boiler's heating surfaces 2. BIOMASS PROPERTIES AND INFLUENCE ON THE CHLORIDE CORROSION PROCESS Biomass is a fuel with properties significantly different from coal. The biomass itself is stronglyGet Price

  • why increase the waste heat boiler chloride – Boilers

    Dec 08, 2021 · The process Process heat from steam boilers Preheating of mill water and chlorine dioxide in chemical. Ask Price View More; An overview of problems and solutions for components subjected to . In waste heat boilers, the heat of exhaust flue gases coming from The deposited alkali chlorides may increase the corrosion rate of super . Ask Price View Get Price

  • What could high content of chloride impose or affect to

    Oct 08, 2021 · When the high concentration of chloride ions enter the boiler, it will cause two kinds of damage: one is that the chloride ions destroy the integrity of the protective film on the metal surface of the furnace tube. Because the chloride ion is an activated anion, it can preferentially adsorb to the defects indicated by the metal in the water.Get Price

  • Chloride Test In Boiler Water - rubivan.co.uk

    Boiler Water Chloride Test Kits Boiler Chloride Test Kits comes in 1 drop = 2, 5, and 10 ppm. Directions: Fill the vial with 25 ml of boiler water. Read More. ENERGY STAR | The Simple Choice for Energy Efficiency. ENERGY STAR® is the simple choice for energy efficiency. For more than 20 years, EPA's ENERGY STAR program has been America's Get Price

  • What is makeup water in a boiler? - FindAnyAnswer.com

    Feb 20, 2020 · The boiler receives the feed water, which consists of varying proportion of recovered condensed water (return water) and fresh water, which has been purified in varying degrees (make up water). The make - up water is usually natural water either in its raw state, or treated by some process before use.Get Price

  • chloride content in boiler water – Industrial Boiler Supplier

    2 years ago coal power boiler plant in china 2 years ago water boiler water boiler manufacturers 2 years ago price of 2 ton steam boiler 2 years ago china high quality gas fired boiler 2 years ago gas boiler prices boiler supplier chloride content in boiler water. Posted On : Liming Published By : Get Price

  • Chlorides & Steam — Heating Help: The Wall

    Apr 01, 2006 · Testing of boiler water for large steam boilers needs to become a routine to MAINTAIN chloride levels below 100ppm. Bottom blowdowns are a necessary evil where boiler water treatment is concerned. Welding is a costly alternative. You may have to some frequent bottom blowdowns and test to lower the chlorides, then start testing daily and keep a Get Price

  • Sodium Monitoring TECHNICAL NOTE On Power Plant

    Extensive on-line chemical monitoring of both the water/ steam cycle and the water treatment plant on modern power stations, is now a very well established practice. This enables careful control of the water chemistry to achieve peak efficiency and minimise downtime due to excessive boiler corrosion or scaling.Get Price

  • Chloride level in Boiler feed water - Corrosion

    Mar 04, 2019 · The amount of chloride in the boiler water is a function of the type of boiler and the boiler pressure. High pressure utility boilers have essentially zero chlorides. For low pressure industrial boilers say 150 psi units, boiler water chlorides limits are set on the ideas thatGet Price

  • Noobie Question: How To Treat Water (Water Report)

    Jan 03, 2022 · homeburrero wrote:That water's 120-130 mg/L hardness and 93-100 mg/L alkalinity numbers indicate that it would deposit some scale at steam boiler temps -- at 125C it might deposit 50 - 60 mg of limescale per liter of water fed into the boiler.(See Jim Schulman's Insanely Long water FAQ for scale estimation info). To avoid periodic descaling you could …Get Price

  • Chloride Test In Boiler Water

    Boiler water has to concentrate, will take several days High blowdown Check blowdown valves for leakages Chlorides far too high Chloride Test 1. Take …Get Price

  • How to test boiler water chloride-Water chloride

    Chloride measurement method: take 100ml water sample, add 2-3 drops of phenolphthalein, if it is red, neutralize with sulfuric acid solution to colorless, add 1.0ml 10% potassium chromate indicator, use silver nitrateGet Price

  • Nitrite, Chloride, P-Alkalinity and pH Test

    Chlorides lower than 20 ppm Boiler newly filled with demineral-ized or evaporated water Boiler water has to concentrate, will take several days High blowdown Check blowdown valves for leakages Chlorides far too high Low quality feed water Only use demineralized or evaporated water Check evaporator Sea cooling water leakageGet Price

  • effect of chloride ion on boiler water

    The effect of water characteristics on steam quality can be verified with steam purity testing. The hydroxide ion present in many boiler waters is highly conductive compared to the other ions. Because chlorides do not precipitate in the boiler water, the relative chloride concentrations in feedwater and boiler water provide an accurate . Learn MoreGet Price

  • Effects Of The Seawater In Steam Boiler

    Kefid · Boiler water carryover is the contamination of steam with boiler water solids. Common causes of boiler water carryover are: Bubbles or foam form on the surface of the boiler water and leave with the steam. This is due to high concentrations of insoluble or soluble solids in the boiler water.Get Price

  • BOILER AND COOLINGWATER TESTKIT Nitrite, Chloride, P

    BASIC WATER TREATMENT OF STEAM BOILERSGet Price

  • CN104568947A - Method for quickly judging trace chloride

    The invention relates to a method for quickly judging trace chloride ions in test boiler water of a boiler. The method comprises the following steps: (1) putting 200ml of the test boiler water of the boiler, to be detected, in a triangular flask; (2) preparing a standard solution with the concentration of chloride ions of 0.2mg/L, and dropwise adding 2ml of 0.1mmol silver nitrate …Get Price

  • MarineExchange - Chlorides in the boiler water | Facebook

    Chlorides in the boiler water. See more of MarineExchange on Facebook. Log InGet Price

  • BASIC WATER TREATMENT OF STEAM BOILERS

    Drain and cool down the boiler. Plug the tube from the water/stem drums side. Plugs may be inserted from the gas side as well after step 3. Half cut plugged water tube. Put stoppers or seal plates from the gas side in the top and bottom of the cut pipe. Weld stoppers/seal plates to seal the steam and water drums.Get Price

  • (PDF) Chloride Contamination of the Water/Steam Cycle in

    Unit load versus CEP sodium and boiler chloride and sulphate concentrations, and continuous blowdown (CBD) rate for periods directly preceding (February 19, …Get Price

  • Recommended ABMA & ASME Boiler Water Limits Boiler …

    eventually scale, which deposits on the internal surfaces of the boiler. The result: a serious loss of boiler efficiency, and possibly boiler failure. Scale is a buildup of solid material formed on internal boiler surfaces when the concentration of impurities in the boiler water exceeds their solubility limit and precipitation occurs.Get Price

  • Combined-Cycle Water/Steam Monitoring - Power Engineering

    Nov 14, 2013 · Boiler water pH is one of the few samples where an immediate unit shutdown is required if the chemistry goes bad. EPRI calls for immediate shutdown if the pH drops below 8.0 although I am aware of Get Price

  • High chloride

    SPECTRAPAK 315. Spectrapak™ 315 - Low Pressure Boiler Water Test Kit, Parameters: P. ALKALINITY, CHLORIDE and pH. Compact portable boiler water test kit. Please note that oxygen scavenger testing is provided separately (Spectrapak™ 312 for Hydrazine. Spectrapak™ 313 for DEHA and Sulphite test kit for Sulphite). Product number: 739490.Get Price

  • (PDF) Chloride Contamination of the Water/Steam Cycle …

    Preventing of blowback in boilers. A high pressure, oil fired steam boiler operates with an automatic combustion control system for start, stop and modulation of the burners. Which feature of the combustion control system is intended to minimise the risk of blowback during normal operation? Pre-purge of the furnace prior to burner ignition.Get Price

  • Why and How; Detecting Sugar within Boiler Condensate

    Jan 12, 2016 · Sugar breaks down into acids, at high temperatures, causing foam, corrosion and scale inside of the boiler, this cause's considerable damage to the boiler and its accessories.Get Price

  • BOILER WATER TEST – MEO EXAMS PREPARATION

    Jun 09, 2017 · chloride test:- is carried out to find out presence of chlorine in boiler water which can lead to corrosion. chlorine presence in boiler water means ingress of sea water in boiler water most probably from dump/vacuum condenser. test procedure:-a) p-alkalinity sample+ 2ml h2so4. b) then add 20 ml potassium chromate.Get Price

  • 【YT-Z】 Boiler Water Testing Equipment (Chloride ion)

    About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators Get Price

Discount
7X24 Online